HERBEST × GIMER MEDICAL

StimON Pro

Wearable Pain Relief System

Pain care that fits everyday life. A lightweight wearable design with independently adjustable dual channels brings each 30-minute session into your daily routine.

STP901 | Taiwan Medical Device Manufacturing License No. 008765

48 g

Lightweight device

2 channels

Independent intensity control

Levels 0–5

Adjust gradually to comfort

30 minutes

Automatic session shut-off

MEET STIMON PRO

Meet your everyday pain-care companion

Watch Gimer Medical’s introduction to the product design and everyday use.
Watch on YouTube ↗

DESIGNED FOR EVERYDAY CARE

Designed around everyday care

For adjunctive treatment of chronic intractable pain and postoperative or post-traumatic pain, and to help relieve peripheral nerve numbness. Follow your physician’s advice and the instructions for use to determine suitability and electrode placement.

Lightweight and wearable

The 48 g device is easy to carry. Apply the electrodes as directed in the instructions before use.

Dual-channel control

Adjust the intensity of each output independently. Both channels must be used by the same person.

Timed sessions

The device switches off automatically after 30 minutes. Start at level 0 and increase gradually according to comfort.

PLACEMENT GUIDE

Correct placement for every session

Each channel uses two electrode pads. Explore common placement areas below and ask your physician to guide placement for your pain location.

Lower back

Position the two pads vertically on the same side of the lower back, away from the centre of the spine.

Shoulder

Arrange both pads on the same shoulder as illustrated. Do not apply to the front of the neck.

Wrist / forearm

Arrange both pads along the inner forearm as illustrated, on intact, dry skin.

Knee

Place both pads around the knee as illustrated, avoiding wounds and irritated skin.

Do not position pads across the chest, over the heart, on the front of the neck or at other prohibited sites.

GETTING STARTED

From setup to storage in four steps

Use one pair of pads per channel. Two channels require two pairs, and both channels must be used by the same person.

01

Prepare your skin

Make sure the device is off. Clean and dry the application area without applying lotion or oil.

02

Connect and apply

Securely connect the lead to the device and both pads. Apply at the instructed positions, ensuring the pads lie flat without lifted edges.

03

Start and adjust

Hold the power button for approximately one second. Start at level 0 and adjust each channel gradually from low to a comfortable intensity.

04

Finish and store

The device switches off after 30 minutes. Once it is off, remove the pads, replace them on their protective liners, and store them sealed.

SPECIFICATIONS

Compact design. Clear specifications.

Model

STP901

Device dimensions

70 × 70 × 15.7 mm

Device weight

48 g

Output channels

2, independently adjustable

Intensity settings

Levels 0–5 (6 levels)

Session duration

30 minutes; automatic shut-off

Charging time

Approximately 120 minutes

Runtime on a full charge

Approximately 600 minutes

Charging interface

USB Type-C

Taiwan medical device license

Manufacturing License No. 008765

Specifications are based on the manufacturer’s instructions. Use the designated electrode pads, which are sold separately. Please confirm the supplied accessories when enquiring.

BEFORE YOU BEGIN

Read before use

Who can use it?

For adults aged 18 or over who have no cognitive impairment and can read the instructions. Consult a physician first to determine whether the device is suitable for you.

Who must not use it?

Do not use if pregnant or possibly pregnant, if you have epilepsy, an implanted pacemaker, defibrillator or other electronic device, or an allergy to hydrogel.

Where must pads not be applied?

Do not apply to the front of the neck or carotid artery, the chest over the heart, eyes, body cavities, acute or surgical wounds, or inflamed or diseased skin.

Can it be used while charging?

Do not use while charging, driving, or operating machinery.

What if discomfort occurs?

Stop use and consult a physician if pain worsens, skin irritation develops, or other discomfort occurs. Read the supplied instructions for all precautions.

Read the instructions before use. Follow professional guidance for electrode placement and operation.

GIMER MEDICAL

Discover more about StimON Pro

Visit Gimer Medical’s StimON Pro page ↗

Sources: Gimer Medical StimON Pro product information, the manufacturer’s STP901 instructions for use, and Taiwan medical device license information.